REMOTE THERMOMETER INFORMATION
Capillary Length:
Capillary Lenghts are +/- 1/8"
Remote Mount Thermometers are Speical Order Items and
are Non-cancellable and Non-Returnable
Probe Length:
SPECIAL PROBE INFORMATION
Probe Diameter:
Probe Length: Inches Centimeters
Probe Lenghts are +/- 1/8 (0.32cm)"
All Thermometers with Special Length Probes
are Non-cancellable and Non-Returnable
Logo:
This item is available for same day shipping with a 20% expedite fee if:
- You have an account with us and are in good standing
- We receive a written purchase order by 3:00pm eastern standard time
- The "SHIP TODAY" option shows on the configurator
- Configured with CSE Logo
- Maximum quantity is 5 pieces
Not all items or configurations are available for same day shipping. For a list of items that qualify please click the link below:
Same Day Ship Item List
Options:
with Special Length Probes
are Non-cancellable
and Non-Returnable
SPECIFICATIONS:
Compliance:
Accuracy:
Resolution:
Units of Measure:
LCD Display Size: 1" (2.54 cm)
Refresh Rate: Every One Second
Process Temperature Range:
Ambient Operating Limits:
Ambient Storage Limits:
Product Contact Material: 316L Stainless Steel
Product Contact Finish:
Case & Lens Ring Material: 304L Stainless Steel
Lens Material: 1/4" Polycarbonate
Power: 2 Standard AAA Batteries
Battery Life Expectancy: 1 to 3 Years
Approx. Shipping Weight:
RTD Output Specifications:
Connector: Std. 12mm Industrial Connector
Type: Pt-100 Thin Film: Class A RTD
Tolerance: F 0.15 (Class A)
Nominal Resistance: 100Ω at 0°C (32°F)
Coefficient: Alpha = 0.00385 Ohms/Ohm/°C
Specification: DIN EN 60751 / IEC751
Long Term Stability: Max. R0-Drift 0.04% after 1000 hrs at 500°C (932°F)
Measuring Current: 0.3 to 1.0 mA
Transmitter Output Specifications:
Connector: Std. 12mm Industrial Connector
Typical Accuracy: ± 0.15% of Scale
Range: factory or field rangeable -30°C to 150°C (-22°F to 302°F)
Input: 6 to 32 VDC)
Output: 4 to 20 mA (temperature linear)
Resolution: 5µA (0.005mA)
Linearity: ±0.1% of span
Long-term Stability: ±0.05% of span/year
Output Load: RLoad = (Vsupply - 8.0V)/0.022
Sensor Failure Detection (burnout): Upscale
Isolation: Not Galvanically Isolated
Calibration: Field Calibratable, Zero and Span Adjustable, Rangeable
Zero Adjustment: Any value within range limits
Minimum Span: 20°C (36°F)
Configure a Part Number | Specifications | Outline Drawings | Brochure | Battery Replacement & Recalibration