Sani-Flow Digital Thermometer Specifications

Thermometer

CSE DIGITAL THERMOMETER:

Compliance: More Info - Compliance 3-A, NEMA 4X, IP67: ISO 9001:2015
COMPLIANCE

close 3-A Conforms to 3A 74-05 Sanitary Standards for Sensors and Sensor Fittings and Connections Used on Milk and Milk Products Equipment.

3-A Sanitary Standards, Inc. (3-A SSI) is an independent, not-for-profit corporation dedicated to advancing hygienic equipment design for the food, beverage, and pharmaceutical industries.

NEMA 4 enclosures are used indoors and outdoors to house such items as electrical/ electronic controls, instrumentation systems, and pneumatic, hydraulic and machine tool controls. These enclosures are designed to provide protection against dust, dirt, oil and water. They are suitable for use in areas such as dairies, breweries and similar environments where they are subject to frequent high pressure hosing and generally wet conditions.

IP67 - IP means "Ingress Protection". IP67 enclosures are rated as "dust tight" and protected against the effects of temporary immersion in water.

cse
Accuracy: More Info - Accuracy ± 0.5°F (± 0.3°C)
ACCURACY

close Accuracy is defined as the conformity of an indication to its true value. Accuracy is ± (plus or minus) a stated value across the full range. For example, a thermometer that has an accuracy of ±1/2° would mean that the thermometer can be off no more than ±0.5° anywhere within its range.

cse
Resolution: More Info - Resolution 0.1°F or °C (Full Scale)
RESOLUTION

close Resolution
The resolution of a thermometer is to what fraction of a degree it is possible to make a reading. (0.1°F or °C)

cse
Units: More Info - Units °F or °C - Field Selectable
UNITS

close Switchable

LCD Display Size: More Info - LCD Display Size 1" (2.54 cm)
LCD DISPLAY

close Display The high contrast LCD's numerals are one inch tall (2.54cm).

Refresh Rate: More Info - Refresh Rate Once per Second
REFRESH RATE

close The refresh rate is how often the thermometer takes a reading and displays the result.

cse
Product Contact Finish: Ramax = 8 µin (0.20 µm)
Product Contact Material: 316L Stainless Steel
Case & Lens Ring Material: 304L Stainless Steel
Lens Material: 1/4" Polycarbonate
Process Temperature Range: More Info - Process Temperature Range -58° to 302°F (-50° to 150°C)
PROCESS TEMPERATURE RANGE

close This is the temperature range which the thermometer is able to measure.

cse
Ambient Operating Limits: More Info - Ambient Operating Limits -40° to 176°F (-40° to 80°C)
AMBIENT OPERATING LIMITS

close This is the temperature range of the environment which the thermometer is able to operate within. If the electronics within the case of the thermometer should go above or below these temperature limits, the thermometer will not operate properly.

cse
Ambient Storage Limits: More Info - Ambient Storage Limits -40° to 185°F (-40° to 85°C)
AMBIENT STORAGE LIMITS

close This is the temperature range of the environment which the thermometer can be stored. If the electronics within the case of the thermometer should go above or below these temperature limits, the thermometer might be damaged.

cse
Power: 2 Standard AAA Batteries
Battery Life Expectancy: 1 to 3 Years
Approx. Shipping Weight: 2 Pounds (0.9 Kg)

CSE DIGITAL THERMOMETER - RTD OUTPUT (optional):

Connector: Std. 12mm Industrial Connector

(Gold Plated Copper Contacts with

Polyphthalamide (PPA) Keyed Insert)
RTD Type 3-Wire Thin Film
RTD Tolerance F 0.15 (Class A)
Nominal Resistance 100Ω at 0°C (32°F)
Coefficient Alpha = 0.00385 Ω/Ω/°C
Specification DIN EN 60751 / IEC 751
Long-Term Stability Max R0 Drift- 0.04% after
1,000 hrs. at 500 °C (932 °F)
Measuring Current 0.3 to 1.0 mA

CSE DIGITAL THERMOMETER - TRANSMITTER OUTPUT (optional):

Connector: Std. 12mm Industrial Connector

(Gold Plated Copper Contacts with

Polyphthalamide (PPA) Keyed Insert)
Typical Accuracy ± 0.15% of span
Range -30° to 150°C (-22° to 302°F)
Type 2-Wire Analog
Input 6.5 to 32 VDC
Output 4 to 20 mA (temperature linear)
Linearity ± 0.1% of span
Long-Term Stability ± 0.1% of span/year
Output Load RLoad = (Vsupply – 6.5V)/0.025
Sensor Failure Detection (burnout) Upscale
Isolation Non-isolated

Download a PDF of These Specifications


Configure a Part Number | Specifications | Outline Drawings | Brochure | Battery Replacement & Recalibration

Copyright © 2024 Chicago Stainless Equipment, Inc. All rights reserved.