Sani-Flow Digital Thermometer Specifications

CSE DIGITAL THERMOMETER:

Conforms to 3A 74-05 Sanitary Standards for Sensors and Sensor Fittings and Connections Used on Milk and Milk Products Equipment.
3-A Sanitary Standards, Inc. (3-A SSI) is an independent, not-for-profit corporation dedicated to advancing hygienic equipment design for the food, beverage, and pharmaceutical industries.
NEMA 4 enclosures are used indoors and outdoors to house such items as electrical/ electronic controls, instrumentation systems, and pneumatic, hydraulic and machine tool controls. These enclosures are designed to provide protection against dust, dirt, oil and water. They are suitable for use in areas such as dairies, breweries and similar environments where they are subject to frequent high pressure hosing and generally wet conditions.
IP67 - IP means "Ingress Protection". IP67 enclosures are rated as "dust tight" and protected against the effects of temporary immersion in water.


Accuracy is defined as the conformity of an indication to its true value. Accuracy is ± (plus or minus) a stated value across the full
range. For example, a thermometer that has an accuracy of ±1/2° would mean that the thermometer can be off no more than ±0.5° anywhere within its range.


The resolution of a thermometer is to what fraction of a degree it is possible to make a reading. (0.1°F or °C)



The high contrast LCD's numerals are one inch tall (2.54cm).

The refresh rate is how often the thermometer takes a reading and displays the result.


This is the temperature range which the thermometer is able to measure.


This is the temperature range of the environment which the thermometer is able to operate within. If the electronics within the case of the thermometer
should go above or below these temperature limits, the thermometer will not operate properly.


This is the temperature range of the environment which the thermometer can be stored. If the electronics within the case of the thermometer
should go above or below these temperature limits, the thermometer might be damaged.

CSE DIGITAL THERMOMETER - RTD OUTPUT (optional):
(Gold Plated Copper Contacts with
Polyphthalamide (PPA) Keyed Insert)
CSE DIGITAL THERMOMETER - TRANSMITTER OUTPUT (optional):
(Gold Plated Copper Contacts with
Polyphthalamide (PPA) Keyed Insert)